1) Login into CLI of F5 LTM.
2) Get into TMSH
# TMSH
3) Configure the following command
# modify /sys db mcpd.mvenabled value true
2) Get into TMSH
# TMSH
3) Configure the following command
# modify /sys db mcpd.mvenabled value true
4) Change the name of the Virtual Server
# mv ltm virtual [old name of the virtual server ] [new name of the virtual server ]
# mv ltm pool [old name of the pool ] [new name of the pool]
# modify /sys db mcpd.mvenabled value false
Ref: F5.com
Ref: F5.com
What is the Impact(application traffic outage) of changing the vserver object name in a Production device?
ReplyDeleteAnd does it sync to the standby device automatically ?
Better not to do it in the peak time. It will sync to Standby F5.
ReplyDeleteBetter not to do at all. We had serious problems after using mv command. Everything looks good from configuration point of view, but the moved object is not functional totally.
ReplyDeleteAfter config reload (tmsh load sys configuration ... ) it seems ok.
So be careful with mv command.